Pneumatic valve common fault and the solution

    When the pneumatic single-seat control valve graphite asbestos filler, about three months should be added to the filler on a lubricant to ensure flexible and easy to use control valve. If it is found that the packing pressure cap is very low, it should be filled with filler. If it is found that the PTFE packing is hardened, it should be promptly replaced. Attention should be paid to the operation of the regulating valve during the inspection, check the position indicator and the regulator The output is consistent; on the positioner pneumatic single-seat control valve should always check the gas source and found that problems in a timely manner; should always maintain the pneumatic single-seat control valve and the health of all components and easy to use. Pneumatic single seat regulating valve common failures and causes (A) Pneumatic single seat regulating valve does not move. Symptoms and causes are as follows: 1. No signal, no air source. ① gas source is not open; ② due to air source water in winter icing, resulting in duct blockage or filter, pressure regulator plug failure; ③ compressor failure; ④ air mains leakage. 2. Air source, no signal. ① regulator failure; ② signal tube leakage; ③ bellows leak locator; ④ regulatory mesh membrane damage. 3. Locator no air source. ① clogged filter; ② valve failure; ③ pipeline leakage or blockage. 4. Locator has a gas source, no output. The throttle of the positioner is blocked. 5. There is a signal, no action. (1) the spool off; (2) the spool and the social or seat stuck; (3) the valve stem bent or broken; (4) the valve seat block frozen or coke dirt; (B) pneumatic single-seat control valve instability. Symptoms and causes are as follows: 1. Air pressure instability. ① compressor capacity is too small; ② valve failure. 2. Signal pressure is not stable. ① The time constant of the control system (T = RC) is not appropriate; ② The regulator output is not stable. 3. Gas pressure stability, signal pressure is stable, but the control valve action is still unstable. ① locator amplifier ball valve dirt worn lax, air consumption will increase when the output shock will produce; ② locator amplifier nozzle baffle is not parallel, the baffle cover nozzle; ③ output tube , Line air leakage; ④ actuator stiffness is too small; ⑤ stem friction in the movement of large, with the contact parts of the block phenomenon. (C) single-seat pneumatic valve vibration. Symptoms and causes are as follows: 1. The regulating valve vibrates at any opening. ① unsteady support; ② nearby vibration source; ③ valve core and bush wear serious. 2. Regulating valve in the fully closed position near the vibration. ① control valve selected, often used in a small opening; ② single-seat valve medium flow direction and closed the opposite direction. (D) Pneumatic single-seat control valve slow action. The phenomenon of dullness and the reasons are as follows: 1. The stem is only dull when moving in one direction. ① Pneumatic diaphragm actuator diaphragm rupture leakage; ② "O" -type seal leakage in the actuator. 2. Stem in the reciprocating action are slow phenomenon. ① blockage of viscous substances in the valve body; ② polytetrafluoroethylene filler hardening or graphite asbestos filler lubricant drying; ③ packing plus too tight, frictional resistance increases; ④ stem because the valve does not lead to direct friction resistance; ⑤ no Pneumatic positioner valve will lead to slow action. (E) Pneumatic single seat control valve leakage increases. The reasons for the leakage are as follows: 1. The valve leaks when the valve is fully closed. ① spool is worn, serious leakage, ② valve not adjusted off is not strict. 2. The valve does not reach the fully closed position. ① medium pressure is too large, the actuator rigidity is small, the valve is not strict; ② valve foreign body; ③ bushing sintering. (F) adjustable flow rate smaller. The main reason is that the valve core is corroded and smaller, so that the adjustable minimum flow rate becomes larger. Understand the phenomenon of pneumatic control valve failure and the reasons that symptomatic measures can be taken to resolve.

    PEG-150 Distearate

    PEG-150 Distearate is a polyethylene glycol (PEG) ester of stearic acid. It is a white to off-white waxy solid that is used as an emulsifier, thickener, and opacifier in various cosmetic and personal care products, such as lotions, creams, shampoos, and conditioners. It helps to stabilize emulsions and prevent separation of oil and water-based ingredients. It also imparts a creamy and smooth texture to formulations and enhances the spreadability of products on the skin or hair. PEG-150 Distearate is considered safe for use in cosmetics and personal care products, but may cause skin irritation or allergic reactions in some individuals.

    PEG-150 Distearate is a polyethylene glycol derivative of stearic acid. It is commonly used in the cosmetic and personal care industry as an emulsifier, thickener, and surfactant. It helps to create stable emulsions and improve the texture and viscosity of products such as creams, lotions, and shampoos. It is also used in some industrial applications such as lubricants and plastics. PEG-150 Distearate is generally considered safe for use in cosmetics and personal care products, although some people may be sensitive to it

    PEG-150 Distearate Cas No.: 9005-08-7, Polyethylene Glycol PEG-150, Poly Ethylene Glycol/PEG-150

    Sichuan Jinhe Qihang Co,. Ltd. , https://www.jinhechemicals.com

    Previous Post: Instrument and Meter Industry's "Twelfth Five-year" New Situation
    Next Post: Luoyang LYC Bearing Company Adds New Products to Wind Power Product Group
    Home
    Recent Posts
    • Gear occlusion touch non-linear profiling simula…
    • Fans are used in greenhouse ventilation in south…
    • Lighting companies join the trend of online sale…
    • Can buy National Day train ticket from now on
    • China's high-end CNC machine tools must brea…
    • FMC receives $90 million in supply contract
    • New energy vehicles subsidize new government pol…
    • Carefully car in autumn and fall
    • Volvo car is called BMW, Mercedes, aiming to get…
    • 10 Inch Heavy Duty Pneumatic Tyre Fixed Wheel
    • The proportion of powder metallurgy auto parts i…
    • China's economic decline or delays the recov…
    • Australia cancels anti-dumping investigation aga…
    • In 2016, Xinjiang built 3,058 fruit and vegetabl…
    • Lab Glassware Distilling Flask, Boro 3.3
    • The best way to transport food in a refrigerated…
    • Forecast the future development trend of China&#…
    • Online shopping or new car sales point
    • Changzhou Jinling Drying Co., Ltd. Introduces Ru…
    • Test of sugar content and climate change of suga…