Solution to Problems in Wireless Monitoring System Project Engineering

    1. Observe carefully
    Observing is the first method in the debugging judgment process. It runs through the entire debugging process. Observe to be careful and serious.
    (1) Observe the working environment of equipment operation
    There is no shelter around, and if so, can it be avoided by elevating or relaying. In short, it is to ensure that the wireless monitoring equipment works in the public viewing environment.
    (2) Observing similar equipment near the equipment
    Look at other devices will not cause the same frequency interference, there are no sources of electronic interference around.
    (3) Observe each part in a system
    A wireless monitoring system is always formed by a series of devices. Carefully observe each component, including connected gadgets, power supplies, etc., to make sure that everything is OK.
    2, the minimum system method
    The minimum system refers to the most basic hardware and software environment that enables the monitoring system to operate from the perspective of debugging.
    The minimum system method is mainly to determine whether the system can work normally in the most basic software and hardware environment.
    If it does not work properly, it can be determined that the most basic hardware and software components are faulty, and thus function as fault isolation.
    The combination of the minimum system method and the gradual addition method can quickly locate the fault and improve the debugging efficiency.
     
    3, gradually add / remove method
    Gradual addition method, based on the minimum system, adding only one component/equipment or software to the system at a time.
    To check whether the fault phenomenon disappears or changes, to determine and locate the fault location.
    4. The gradual removal method is just the opposite of the gradual addition method.
    Step-by-step addition/removal methods generally work with replacement methods to locate fault locations more accurately.
    5. Alternatives
    The replacement method is a method of replacing a faulty component with a good component to determine whether the fault phenomenon has disappeared.
    1) Good parts can be of the same model or different models.
    The order of replacement is generally:
    According to the phenomenon of failure or failure category in the second part, consider the parts or equipment that need to be replaced;
    Replace in a simple and complex sequence. When judging communication failure, first consider the setting of the communication parameters of the equipment or whether there is a problem with the relevant jumper, and then consider whether the communication line is faulty, and finally consider whether the communication conversion module or the serial port is faulty.
    The first is to check the communication lines, power lines, etc. connected to the parts that are suspected to be defective, then replace the parts that are suspected to be defective, and finally the other parts associated with them.
    2) Consider the component that was replaced first from the failure rate of the component. Parts with high failure rates are replaced first.
    6, the comparison method
    The comparison method is similar to the replacement method, that is, comparing the appearance, configuration, and operation phenomena of a good component and a component that is suspected to be faulty, and can also be compared between two devices to determine the faulty device in an environment setting and hardware configuration. The difference in aspects, so as to identify the fault site.

    Aquarium Filter System

    Aquarium Filter System, Pure Water System, Aquarium DI Water Filter, Aquarium Filter, Fish Tank Filter Online for Sale.

    Provide different Aquarium Pure Water Filter System solutions depends on your local market.
    Any questions, feel free to get in touch with Filterelated team, filterelated@gmail.com are ready to serve you!

    Aquarium Filter System,Pure Water System,Aquarium Filter,Fish Tank Filter

    Filterelated Corp. , https://www.filterelatedcorp.com

    Previous Post: After Market Alloy Wheel 20X9 Forged Alloy Wheel Rim
    Next Post: Street Mobile Mini Fast Food Carts with Shade Window (SHJ-MFS250)
    Home
    Recent Posts
    • 500kgs Permanent Magnetic Lifter/Lifting Magnet
    • Hot Sale Flexible Magnetic Strips for Knife Hold…
    • Mini 1/4′′ 3/8′′ 1/2′′ Inside and Ou…
    • Precautions with remote magnetic flap level gaug…
    • Concept of internal structure of the process
    • Switzerland develops edible temperature sensor t…
    • Historical development and classification of ore…
    • Layout of new energy and the country's six F…
    • How to repair dynamometer
    • "2017 Autopilot "Separate Report"…
    • Ma Stainless Steel Pneumatic Mini Cylinder
    • Grinding machine spindle performance analysis si…
    • Modern teamed up with Beiqi Zhongqi to seek comm…
    • 3D Printer Prototype 5 Axis CNC Prototype 3D Pri…
    • Air Cooled Industrial Chiller for Plastic Machin…
    • The high-speed rail stock market evaporates 39.9…
    • ISO DIN ANSI Kana JIS Standard Plastic Bevel Gea…
    • Bridgestone North American Technology Center awa…
    • Seized 200 orders Yuchai YC6K engine won the fav…
    • Twisting method for bevel gear thermal distortio…